The Conport NorthlightTM Studio

Example Technical Specifications

Building span (variable if required)

9.3 m

Building length module

3.0 m

External ridge height

4.8 m

Gutter height

3.4 m

Standard door height

2.0 m

Standard double door width

1.5 m

Design

Designed in accordance with "European recommendations for the stressed skin design of steel buildings" and relevant British Standards.

External Cladding

Cladding choices are available to suit client requirements. For economy we usually use HP200 Plastisol coated profiled steel external sheeting. Other options include semi flat sandwich panels and/or parapet walls to conceal the roof line. All cladding material is manufactured from "Galvatite", a hot dipped zinc coated steel. The substrate is of grade Fe E280G commercial quality mild steel with a minimum yield stress of 280 N/mm2 . Galvanised coating is to a minimum thickness of 275 g/m2 with a conventional spangle finish. The steel substrate fully complies with the provisions of British Standard BSEN 10147: 1992.All steel is profile rolled to comply with the provisions of BS 5427: 1976 in respect of materials, design, handling, working, performance and storage.

Steelwork

Main Frame hot rolled steel sections.
Secondary steel framework cold rolled sections.

Steel work includes:

  • Hot rolled Veerendeel trusses and supporting stanchions @ 3m c/c.
  • Cold formed sheeting rails.
  • Holding down bolts and erection bolts.

Protection

All hot rolled steel members shall be shot blasted to standard SA2.5 at works prior to fabrication. After fabrication one coat of good quality zinc phosphate primer shall be applied by airless spray to 75 microns nominal thickness. All cold formed members shall be manufactured from pre galvanised strip.

Bolts

Anchor bolts shall be black and be complete with anchor plates nuts and washers. Erection bolts shall be zinc plated.

Doors

Steel insulated double hinged doors with all furniture.

Insulation

Sound reducing insulating quilt to meet Building regulations. Rubber strip to eliminate cold bridging.

Windows

Fixed light double-glazed windows with 4 top hung opening casements in each bay.